Cinefluorography
A cinefluorography produces a movie (cine) film from an image intensifier during x-rays examinations (often called videofluorography, cineradiography or cine). Cinefluorography is always monitored on the TV screen normally used for fluoroscopy. The image from the output screen of the image intensifier is split with a semi-transparent mirror into two output ports; one leading to the movie camera and the other to the fluoroscopy camera. Most of the light is directed to the cine camera. The image on the monitor does not suffer in quality due to the fact that the tube current for cinefluorography is about 100 times higher than for common fluoroscopy.
The x-ray generator pulses are synchronized with the movements of the cine camera, so that no x-rays are emitted when the film is moved forward to the next frame. The needed very accurate synchronization of the x-ray generator can be achieved by use of high voltage switching in the secondary circuit of the constant potential x-ray generator, by starting and stopping the inverter in a medium frequency generator or by using a grid controlled x-ray tube.
Couch Increment
The couch increment is the distance by which the position of a patient table is changed between individual slices. In spiral CT scanning the couch increment is the change of the table position during one 360° rotation of the x-ray tube.
Detail Detectability
The highest amount of detail that can be shown in an image. Defined by the size of the smallest object that can be conveniently viewed, which for nanofocus and microfocus x-ray tubes is about half the size of the focal spot.
Filter Grid
Filter grids are used to reduce scattered noise and increase contrast in x-ray images. Primary radiation passing through an object gets scattered caused by the various density of different materials. Scatter radiation produces noise (radiographic fog) on the film or detector, which degrades the diagnostic quality. Anti-scatter grids act as filters between patient and film (or receiver) to remove scatter radiation. The use of a grid is recommended with body parts thicker than 10 cm and kVp values about 60 kV.
X-ray filter grids are available with focused or parallel strips. These two types are produced with linear or crossed grid configurations. The septa of filter grids consist of high radiation absorbing materials (e.g. lead) separated by permeable parts. During radiation exposure, movement of the grid blurs a projection of the septa.
If the image receptor and x-ray tube (with the focal spot) are in a fixed position relative to one another the grid is automatically aligned. In mobile radiography, the position of the focal spot and the image receptor is variable. Additionally cassettes incorporating anti-scatter grids are also available.
Fluoroscope
A fluoroscope projects x-ray images in a video sequence (movie) onto a screen monitor.
Early generation fluoroscopes presented particularly difficult viewing challenges for radiologists. The human retina contains two types of image receptors. Cones (central vision) operate better in bright light, while rods (peripheral vision) are more sensitive to blue-green light and low light. Therefore, the radiologists wear red goggles to filter out blue-green wavelengths to allow the rods to recover peak sensitivity before viewing fluoroscopic images.
To avoid this time consuming accommodation, the industry developed the image intensifier tube in the 1950s. Due to the high amount of individual images during a fluoroscan, a very sensitive amplifier is needed to cut down radiation exposure. Until today, image intensifiers amplify the faint light emitted by the fluorescing screen and the images can be viewed on a monitor. Recently, digital technique replaces the large and bulky image intensifier with flat-panel technology.
Various other components of a fluoroscope system include a gantry, patient table, x-ray tube, filters, collimators, images sensor, camera and computer, most similar to other radiographic systems.
A fluoroscopy system provides the view of moving anatomic structures and is valuable in performing procedures that require continuous imaging and monitoring, such as barium studies, gastrointestinal function tests, cardiac functions, studies of diaphragmatic movement, or catheter placements. A number of technologies are available to record images created during fluoroscopic (fluorographic) exams.
Result Pages :
...
...
 
Share This Page
Facebook
Twitter
LinkedIn
Look
      Ups
Radiology - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2024 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertising
 [last update: 2023-11-06 02:01:00]