(EMR) Electromagnetic radiation consists of an electric and a magnetic field component. All EMR travels in a vacuum at the speed of light. EMR is classified related to the frequency//length of the wave. An EM wave consists of discrete packets of energy, named photons (quantization). The energy of the photons depends on the frequency of the wave. Planck-Einstein equation: E = h * f E (energy); h (Planck's constant); f (frequency) EMR types include in order of increasing frequency//decreasing wavelength: radio waves, microwaves, infrared radiation, visible light, ultraviolet radiation, x-rays and gamma rays. EMR contains energy and momentum, which may be imparted when it interacts with matter. See Gamma Radiation. • View NEWS results for 'Electromagnetic Radiation' (1). •
A fluoroscope projects x-ray images in a video sequence (movie) onto a screen monitor. Early generation fluoroscopes presented particularly difficult viewing challenges for radiologists. The human retina contains two types of image receptors. Cones (central vision) operate better in bright light, while rods (peripheral vision) are more sensitive to blue-green light and low light. Therefore, the radiologists wear red goggles to filter out blue-green wavelengths to allow the rods to recover peak sensitivity before viewing fluoroscopic images. To avoid this time consuming accommodation, the industry developed the image intensifier tube in the 1950s. Due to the high amount of individual images during a fluoroscan, a very sensitive amplifier is needed to cut down radiation exposure. Until today, image intensifiers amplify the faint light emitted by the fluorescing screen and the images can be viewed on a monitor. Recently, digital technique replaces the large and bulky image intensifier with flat-panel technology. Various other components of a fluoroscope system include a gantry, patient table, x-ray tube, filters, collimators, images sensor, camera and computer, most similar to other radiographic systems. A fluoroscopy system provides the view of moving anatomic structures and is valuable in performing procedures that require continuous imaging and monitoring, such as barium studies, gastrointestinal function tests, cardiac functions, studies of diaphragmatic movement, or catheter placements. A number of technologies are available to record images created during fluoroscopic (fluorographic) exams. •
Gamma rays are a form of nuclear radiation that consists of photons emitted by radioactive elements from the nucleus. This high energetic light emission is also produced from subatomic particle interaction, such as electron positron annihilation. Gamma radiation, similar to x-radiation can injure and destroy tissue, especially cell nuclei. Gamma rays have in general very high frequencies, short wavelengths, are electrically neutral and penetrate matter. The interaction of gamma rays with matter depends on the nature of the absorber as well as the energy of the gamma rays; these interactions determine also the type and amount of shielding needed for radiation protection. See also Radiation Safety, Lead Equivalence, Lead Apron, Leaded Glove, Glove-Box, Radioactive Decay Law and Radiation Worker. Further Reading: News & More:
•
Mammography is a diagnostic imaging procedure of the breast to detect and evaluate breast disease. Mammography is widely used as a screening method and plays a key role in early breast cancer detection. The screening mammography is used to detect breast changes in women who have no signs or symptoms or noticed breast abnormalities. The goal is to detect a breast tumor before any clinical signs are observable. A diagnostic mammography is used to investigate suspicious breast changes, such as a breast lump, an unusual skin appearance, breast pain, nipple thickening or nipple discharge. A breast screening or standard mammography requires two mammograms from different angles of each breast including craniocaudal view and mediolateral view. Additional images can be made from other angles or focus on microcalcifications or other suspicious areas. A mammogram is created by special mammography equipment with long wavelength of the used x-rays. Film-screen mammography is still the most widely used technology, but the state of the art technique is digital mammography. Conventional x-ray equipment was used to produce mammograms until dedicated mammography equipment became available in the late 1960s. Film-screen mammography and xeromammography, introduced in the early 1970s, used lower radiation doses and produced sharper mammograms. The second generation of mammography systems has been introduced in the early 1980s. Chief disadvantages of analog mammography include the labor-intensive handling of the cassettes, relatively slow processing time, the lack of a direct interface to the x-ray system, and no post processing possibilities. Mammograms of high quality should be done with the lowest radiation dose as possible. Adequate breast compression is important due to shortening of the exposure times, immobilization of the breast, reduction of motion and blurring and prevention of overpenetration by means of equalizing breast thickness. Further breast imaging procedures include breast ultrasound and breast MRI. Further Reading: Basics:
News & More:
•
A photon is a discrete packet of electromagnetic energy. The amount of energy depends on the frequency (wavelength) of the photon. Highest frequency, most energetic photon radiations are gamma rays, up to 300 EHz - 1.24 MeV. In addition to energy, photons are also carrying momentum. Photons have no electrical charge or rest mass and exhibit both particle and wave behavior. Photons are traveling in vacuum (without interactions with matter) with the constant velocity of 2.9979 x 108 m/s (c, speed of light). Photons get absorbed or scattered away from their original direction of travel when interacting with matter. High energy photons as for example x-rays cause damages to exposed tissue and cells. Radiation exposure is measured in roentgen, radiation absorption in Roentgen//min. Photon radiation in the frequency ranges of x-rays and gamma rays are used for medical diagnostic and treatment. See also Photon Energy and Gamma Ray. Further Reading: Basics:
News & More:
Result Pages : |