Adverse Reaction
Adverse reactions on contrast agents are rare, but like all other pharmaceuticals, contrast media are not completely without side effects.
Adverse effects to contrast media include allergic symptoms, anaphylactoid reactions, chemotoxic reactions, idiosyncratic reactions, contrast-induced nephropathy, iodide-induced hyperthyroidism and local tissue damage. An adverse reaction can be related to dose, the toxicity, and the physio-chemical properties of the contrast agent, for example osmolality, viscosity, and hydrophilicity.
Side effects such as a metallic taste in the mouth, generalized warmth or flushing, nausea and vomiting, increase with rapid flow and large volume of the injected agent. Although venous tolerance is usually good, there have been reports of sensation like burning, stinging or numbness and of venospasm.

Characterization of adverse reactions include:
•
Allergic drug reactions never occurs on the first exposure, but it can occur even with small amounts.
•
Chemotoxic reactions result from the properties and characteristics of the used drug, the dose, speed of injection, etc. Hemodynamic disturbances and injuries to organs or vessels perfused by the contrast agent are included.
•
Idiosyncratic reactions can occur on first exposure to the contrast medium. And unlike a side effect, the reaction occurs only in susceptible individuals, probably due to a genetic or metabolic abnormality.
• 
View NEWS results for 'Adverse Reaction' (1).Open this link in a new window.
•
Data Acquisition
Data acquisition is the generation of data that can be manipulated with a computer.
•
Direct Radiation
Direct radiation is emitted from the target or source that passes though the collimator opening.
•
Image Resolution
Image resolution is a measurement of the scanned, printed, or displayed image quality. Picture resolution on a printed photo or page is measured in dots per inch (DPI). For digital files, image resolution is expressed in pixels per inch (PPI).
The quality of pixel-based images is directly determined by resolution choices. Higher image resolution results in more detailed images but requires more storage space in a picture archiving and communication system.
The resolution for x-ray images can be defined as the period length of the finest grid that can be viewed without difficulty.
•
Nonionic Monomer
Nonionic monomers are used as x-ray contrast agents. To create a nonionic monomer, the tri-iodinated benzene ring is made water soluble by the addition of hydrophilic hydroxyl groups to organic side chains (CM ratio=3). Nonionic monomers have an intermediate osmolarity, intermediate viscosity and elevated hydrophilicity with three atoms of iodine per molecule. Lacking a carboxyl group, nonionic monomers do not ionize in solution. A nonionic monomer is potentially less chemotoxic than an ionic monomer.
Common nonionic monomers are iohexol (Omnipaque), iopamidol (Isovue®), ioversol (Optiray®), and iopromide (Ultravist®). Nonionic monomers are contrast agents with a wide range of indications due to their nonionic nature and lower osmolalities.
Result Pages :
 
Share This Page
Facebook
Twitter
LinkedIn
Look
      Ups
Radiology - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2025 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertising
 [last update: 2025-04-05 02:37:00]