'Intensifying Screen' Searchterm 'Intensifying Screen' found in 1 term [ • ] and 7 definitions [• ]Result Pages : • Intensifying Screen
An intensifying screen is used to intensify the x-ray effect during radiation exposure of the x-ray film. Approximately 5% of the x-ray photons will be absorbed by the film only. Intensifying screens consist of
a sheet of inorganic salts that emits fluorescent light when stroked by x-rays. The fluorescent input and output screens of the image intensifier are very similar to intensifying screens. Calcium tungstate and rare earths are two common salts (also called phosphors) used for intensifying screens. For example, a calcium tungstate (CaWo4) screen can absorb around 40% of the x-ray photons and convert the radiation into light photons. A basic feature of this screen types is related to the position of the k-edge on the energy axis. Tungsten (W) is a heavy element has a k-edge at 69.5 keV, while that for rare earth elements is in around 50 keV. The fraction of x-rays absorbed by a screen is depending on the speed. Factors affecting the speed of a screen:
•
the phosphor type;
•
the x-ray radiation absorption efficiency;
•
the radiation to light intrinsic conversion efficiency;
•
the thickness of the screen.
See also Actinides, Cinefluorography and Added Filtration. •
A cassette is a thin, low x-ray absorption plastic case, for holding the x-ray film. Inside the cassette are intensifying screens for the conversion of x-rays to visible light photons. The intensifying screens are mounted in close contact with the film. Mammography cassettes are equipped with single screens.
Further Reading: Basics:
•
An x-ray film is a photographic film used to generate a visual x-ray image. X-ray films are rarely used as the only radiation detector. Commonly they are used in conjunction with intensifying screens placed in the film cassette, because high resolution films have a poor sensitivity to x-rays. At direct film exposure, only a small amount of x-ray photons will be absorbed and react with the film emulsion. An intensifying screen contains scintillating materials to convert x-ray radiation into light or lows electromagnetic energies. X-ray films provide very good spatial resolution and contrast, but need long exposures times and chemical processing. See also Conventional Radiography and Digital Radiography. •
Conventional (also called analog, plain-film or projectional) radiography is a fundamental diagnostic imaging tool in the detection and diagnosis of diseases. X-rays reveal differences in tissue structures using attenuation or absorption of x-ray photons by materials with high density (like calcium-rich bones). Basically, a projection or conventional radiograph shows differences between bones, air and sometimes fat, which makes it particularly useful to asses bone conditions and chest pathologies. Low natural contrast between adjacent structures of similar radiographic density requires the use of contrast media to enhance the contrast. In conventional radiography, the patient is placed between an x-ray tube and a film or detector, sensitive for x-rays. The choice of film and intensifying screen (which indirectly exposes the film) influence the contrast resolution and spatial resolution. Chemicals are needed to process the film and are often the source of errors and retakes. The result is a fixed image that is difficult to manipulate after radiation exposure. The images may be also visualized on fluoroscopic screens, movies or computer monitors. X-rays emerge as a diverging conical beam from the focal spot of the x-ray tube. For this reason, the radiographic projection produces a variable degree of distortion. This effect decreases with increased source to object distance relative to the object to film distance, and by using a collimator, which let through parallel x-rays only. Conventional radiography has the disadvantage of a lower contrast resolution. Compared with computed tomography (CT) and magnetic resonance imaging (MRI), it has the advantage of a higher spatial resolution, is inexpensive, easy to use, and widely available. Conventional radiography can give high quality results if the technique selected is proper and adequate. X-ray systems and radioactive isotopes such as Iridium-192 and Cobalt-60 for generating penetrating radiation, are also used in non-destructive testing. See also Computed Radiography and Digital Radiography. Further Reading: Basics:
News & More:
•
Direct exposure films are highly sensitive to the direct effect of x-rays rather than in combination with an intensifying screen. However, a film is a relatively inefficient radiation detector and requires relatively
high radiation exposure. The use of rectangular collimation and the highest speed films reduce radiation exposure.
See also Conventional Radiography. Result Pages : |