Noise
Noise is an undesirable background interference or disturbance that affects image quality. The image noise is commonly characterized by the standard deviation of CT numbers in the image of a uniform object (phantom - generally water) relative to the difference in CT numbers between water and air.
Noise is an important limiting factor of CT image quality and is characterized by a grainy appearance, sometimes described as a salt and pepper pattern. Noise as a result of low radiation dose requires a higher tube current (mA) in combination with narrow slices to maintain image noise at an acceptable level.
Archiving
This term usually refers to the storage of patient data and images. Images are best archived in digital form (e.g., on optical disks, DVDs, PACS systems) and not only on films (hard copies, prints). Data compression via a reduction in matrix size, pixel depth or CT numbers, will result in a loss of spatial and contrast resolution. Digital images should be converted into a universal format such as DICOM. Raw data saving is necessary when additional image reconstructions are required.

See also Picture Archiving and Communication System, and Digital Imaging and Communications in Medicine.
Cinefluorography
A cinefluorography produces a movie (cine) film from an image intensifier during x-rays examinations (often called videofluorography, cineradiography or cine). Cinefluorography is always monitored on the TV screen normally used for fluoroscopy. The image from the output screen of the image intensifier is split with a semi-transparent mirror into two output ports; one leading to the movie camera and the other to the fluoroscopy camera. Most of the light is directed to the cine camera. The image on the monitor does not suffer in quality due to the fact that the tube current for cinefluorography is about 100 times higher than for common fluoroscopy.
The x-ray generator pulses are synchronized with the movements of the cine camera, so that no x-rays are emitted when the film is moved forward to the next frame. The needed very accurate synchronization of the x-ray generator can be achieved by use of high voltage switching in the secondary circuit of the constant potential x-ray generator, by starting and stopping the inverter in a medium frequency generator or by using a grid controlled x-ray tube.
Computed Tomography
(CT or CAT scan) Computed tomography is a diagnostic imaging technique, previously also known as computerized axial tomography (CAT), computer-assisted tomography (CAT), computerized tomographic imaging, and reconstructive tomography (RT).
A CT scan is based on the measurement of the amount of energy that a tissue absorbs as a beam of radiation passes through it from a source to a detector. As the patient table moves through the CT scanner, the CT tube rotates within the circular opening and the set of x-ray detectors rotate in synchrony. The narrow, fan-shaped x-ray beam has widths ranging from 1 to 20 mm. The large number of accurate measurements with precisely controlled geometry is transformed by mathematical procedures to image data. Corresponding to CT slices of a certain thickness, a series of two-dimensional cross-sectional images is created.
A CT is acquired in the axial plane, while coronal and sagittal images can be rendered by computer reconstruction. Although a conventional radiography provides higher resolution for bone x-rays, CT can generate much more detailed images of the soft tissues. Contrast agents are often used for enhanced delineation of anatomy and allow additional 3D reconstructions of arteries and veins.
CT scans use a relatively high amount of ionizing radiation compared to conventional x-ray imaging procedures. Due to widespread use of CT imaging in medicine, the exposure to radiation from CT scans is an important issue. To put this into perspective, the FDA considers the risk of absorbed x-rays from CT scans to be very small. Even so, the FDA recommends avoiding unnecessary exposure to radiation during diagnostic imaging procedures, especially for children.
CT is also used in other than medical fields, such as nondestructive testing of materials including rock, bone, ceramic, metal and soft tissue.

See also Contrast Enhanced Computed Tomography.
Digital Subtraction Angiography
(DSA) Digital subtraction angiography is a radiographic imaging technique to visualize the blood vessels in the human body. DSA images are produced by the (computer) subtraction of pre-contrast images (the mask) from images after introduction of a contrast medium. Subtracting background structures and enhancing the contrast provides the visualization of blood vessels in a bony or dense soft tissue environment. The images are produced in real time, as the contrast agent is injected into the blood vessels.
Result Pages :
...
...
 
Share This Page
Facebook
Twitter
LinkedIn
Look
      Ups
Radiology - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2024 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertising
 [last update: 2023-11-06 02:01:00]