'Generator' p2 Searchterm 'Generator' found in 1 term [ • ] and 9 definitions [• ]Result Pages : •
The process of removing, separating the daughter radionuclide from the generator is referred to as elution.
See Generator. •
The nuclide which produces by radioactive decay or nuclear reaction (e.g. in a generator) the daughter nuclide. The daughter nuclide becomes, if not stable, the unstable parent in the next decay.
See also Decay, Decay Chain and Generator. •
A computed tomography (CT) scanner is used to create cross-sectional
slices of different objects. The medical version of CT system scans the human body for tumors or other abnormalities, other versions are used for non-destructive testing in the industry. The CT imaging system includes the moveable gantry and patient table or couch. The gantry is a frame that contains the x-ray source, collimators, filters, detectors, a data acquisition system (DAS), rotational components including slip ring systems and all associated electronics. The x-ray tube and detector system are mounted opposite each other, allowing a rapid and synchronous rotation around the patient table. In older CT scanners a small generator supplied power to the x-ray tube and the rotational components via cables for operation. Up to the 4th generation the CT tube and detectors rotate together around the patient for each slice. CT systems with slip ring technology (the x-ray tube rotates around a stationary ring of detectors) operate without cables and provides continuous rotation of the gantry components without interference of cables. Spiral CT scanners work with a continuous table movement while the x-ray tube is rotating around the patient. Overview about CT scanner generations:
•
1st generation has a pencil beam and one detector;
•
2nd generation has a narrow fan beam and multiple detectors;
•
3rd generation has a wide fan beam;;
•
4th generation is equipped with a detector ring;
•
•
6th generation is the helical (or spiral) CT scanner;
•
7th generation is the multi-detector row CT.
See also Contrast Media Injector, Dual-Head CT Power Injector, Syringeless CT Power Injector. Further Reading: News & More:
•
An imaging plate is used in computed radiography (CR) instead of a conventional film cassette. The imaging plate is coated with photostimulable phosphors. The phosphor layer is doped with special substances to alter the crystalline structure and physical properties. After radiation, the enhanced phosphor material absorbs and stores x-ray energy in gaps of the crystal structure, building a latent image. Usually, the storage phosphors are stimulated with a low-energy laser to release visible light at each point of x-ray absorption. To read-out the image, the plate is inserted into a computed radiography scanner. The scanning laser beam causes the electrons to relax to lower energy levels, emitting light that is captured by a photo-multiplier tube and converted into an electrical signal. The electronic signal is then converted to digital data and can be displayed on laser-printed films, workstations, transmitted to remote systems, and stored digitally. The CR units automatically erase the image plate after the complete scan. Phosphor imaging plates, like film, are stored in cassette format and can be re-used very often if they are handled carefully. Existing conventional x-ray equipment, from generators to x-ray tubes and examination systems, can be used with imaging plates. Further Reading: Basics:
News & More:
•
[Radioactive Isotope]
Radioisotopes are atoms with an unstable nucleus, which try to reach a more stable state by emitting radiation. Through one or more steps down its decay chain a more stable number of protons and neutrons is reached. Approximately 3,800 natural and artificial (fission, generator) radioisotopes exist. Radioisotopes are commonly used in science, industry, and nuclear medicine.
See also Isotope, Decay and Decay Chain. Further Reading: Basics:
News & More:
Result Pages : |