'Direct Current' Searchterm 'Direct Current' found in 1 term [ • ] and 0 definition [• ], (+ 5 Boolean[• ] resultsResult Pages : • Direct Current
(DC) A continuous current that flows in only one direction.
•
(CR) Computed radiography is an imaging technique that uses similar equipment to conventional radiography except that films are replaced by imaging plates. An imaging plate contains photostimulable storage phosphors, which store the radiation level received at each point in local electron energies. The imaging plate is placed under the patient in the same way as conventional film cassettes. After x-ray exposure, the imaging plate is run through a special scanner to read out the image. The digital image can then be processed to optimize contrast, brightness, and zoom. Computed Radiography can be seen as halfway between film-based conventional technology and current direct digital radiography. Further Reading: Basics:
News & More:
•
(H) The region surrounding a magnet (or current carrying conductor) is equipped with certain properties like that a small magnet in such a region experiences a torque that tends to align it in a given direction. Magnetic field is a vector quantity; the direction of the field is defined as the direction that the north pole of the small magnet points when in equilibrium.
Further Reading: Basics:
News & More:
•
A cinefluorography produces a movie (cine) film from an image intensifier during x-rays examinations (often called videofluorography, cineradiography or cine). Cinefluorography is always monitored on the TV screen normally used for fluoroscopy. The image from the output screen of the image intensifier is split with a semi-transparent mirror into two output ports; one leading to the movie camera and the other to the fluoroscopy camera. Most of the light is directed to the cine camera. The image on the monitor does not suffer in quality due to the fact that the tube current for cinefluorography is about 100 times higher than for common fluoroscopy. The x-ray generator pulses are synchronized with the movements of the cine camera, so that no x-rays are emitted when the film is moved forward to the next frame. The needed very accurate synchronization of the x-ray generator can be achieved by use of high voltage switching in the secondary circuit of the constant potential x-ray generator, by starting and stopping the inverter in a medium frequency generator or by using a grid controlled x-ray tube. Further Reading: News & More:
• Result Pages : |