Multi-Head Contrast Media Injector
Multi-head contrast media injectors offer flexible contrast media management, simplified workflows and increased patient safety.
Contrast delivery is much more controlled and efficient when using a dual-head CT power injector. These medical devices are needed to enable the short imaging times typical of multidetector computed tomography (CT) scanners.
Triple-head injectors allow selection of a second contrast agent when two different contrast agents are used, or switching to full contrast agent containers when two identical contrast agents are used.

See also Contrast Media Injector, Syringeless CT Power Injector, Single-Head Contrast Media Injector, CT Power Injector.
Pulse Oximeter
A pulse oximeter is a medical device that displays a digital percentage readout of a calculated value of the hemoglobin that is saturated with oxygen (SpO2).
State Food and Drug Administration
eng.sfda.gov.cn/eng (SFDA) The State Food and Drug Administration of the People's Republic of China was founded in November 2003 and is directly under the State Council. The State Food and Drug Administration is in charge of comprehensive supervision on the safety management of food, health food and cosmetics and is the competent authority of drug regulation. For drug or medical device registration please see the SFDA's Regulatory Guide.
The agency is China's equivalent of the US Food and Drug Administration.
Contact Information
MAIL
State Food and Drug Administration
A38, Beilishi Road
Beijing 100810
P.R. China
FAX
86-010-68310909
Tomography
Tomography is imaging by sections or sectioning to obtain images of slices through objects like the human body. Tomography is derived from the Greek words 'to cut or section' (tomos) and 'to write' (graphein). A device used in tomography is called a tomograph, while the image produced is a tomogram.
The first medical applications utilized x-rays for images of tissues based on their x-ray attenuation coefficient. The mathematical basis for tomographic imaging was laid down by Johann Radon. This type of imaging is used in different medical applications as for example computed tomography, ultrasound imaging, positron emission tomography and magnetic resonance imaging (MRI) also called magnetic resonance tomography (MRT).
Conventional x-ray tomographic techniques show organ structures lying in a predetermined plane (the focal plane), while blurring the tissue structures in planes above and below by linear or complex geometrical motion of the x-ray tube and film cassette.
Basically, computed tomography is the reconstruction of an image from its projections. In the strict sense of the word, a projection at a given angle is the integral of the image in the direction specified by that angle. The CT images (slices) are created in the axial plane, while coronal and sagittal images can be rendered by computer reconstruction.

See also Zonography, Computed or Computerized Axial Tomography, Resolution Element, Radiographic Noise, Intravenous Pyelogram.
Transformer
A transformer is an electrical device operating on the principle of mutual induction to change the magnitude of current and voltage.
Result Pages :
 
Share This Page
Facebook
Twitter
LinkedIn
Look
      Ups
Radiology - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging
Copyright © 2008 - 2024 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertising
 [last update: 2023-11-06 02:01:00]