'Developer' p5 Searchterm 'Developer' found in 1 term [ • ] and 24 definitions [• ]Result Pages : •
Smoothies are barium sulfate suspensions with different flavor. The good taste improves the patient compliance. Smoothies have minor side effects such as nausea, diarrhea and bloating.
Smoothies fast transit time allows imaging the abdomen 30 min and the pelvis 90 min after application.
Drug Information and Specification
NAME OF COMPOUND
Barium sulfate (BaSO4)
DEVELOPER
INDICATION
Bowel opacification
APPLICATION
Oral, rectal
CONCENTRATION
2.1 w/v barium sulfate suspension
450-900 mL
PREPARATION
Ready-to-use product
STORAGE
Store at room temperature
PRESENTATION
250 and 450 mL bottle
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE NOT A SUBSTITUTE FOR THE ACCOMPANYING
PACKAGE INSERT!
•
Ultravist® is an iodinated contrast agent with low osmolality and low viscosity, enabling ease of administration and rapid iodine delivery rate. Ultravist® is available in 4 concentrations. Introduced in Europe 1985 and in the US in 1995, Ultravist® is being used today in over 100 countries worldwide.
See also Low-Osmolar Contrast Media.
Drug Information and Specification
NAME OF COMPOUND
Iopromide
DEVELOPER
INDICATION
Brain and body computed tomography, urography, angiography
APPLICATION
Intravascular
PHARMACOKINETIC
Renal excretion
CHEMICAL BOND
483, 607, 774 mosm/kgH2O
IODINE CONCENTRATION
240, 300 an 370 mg/mL
Depending on the used concentration and imaging procedure
PREPARATION
Ready-to-use product
STORAGE
Store at 25°C (77°F); excursions permitted
to 15° - 30° Celsius (59 - 86° Fahrenheit), protect from light.
PRESENTATION
200 mL and 500 mL bottles
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE NOT A SUBSTITUTE FOR THE ACCOMPANYING
PACKAGE INSERT!
Further Reading: Basics:
News & More:
•
Visipaque is an iso-osmolar contrast agent. The osmolality equal to that of blood and the sodium and calcium concentration in a ratio equivalent to blood provides high patient safety and comfort.
Drug Information and Specification
NAME OF COMPOUND
Iodixanol
DEVELOPER
INDICATION
Brain and body computed tomography, urography, angiography
APPLICATION
Intravascular
PHARMACOKINETIC
Renal excretion
CHEMICAL BOND
290 mosm/kgH2O
IODINE CONCENTRATION
270 and 320 mg/mL
Depending on the used concentration and imaging procedure
PREPARATION
Ready-to-use product
STORAGE
Store at 20°-25°C (68°-77°F); excursions permitted to 15°-30°C (59°-86°F), protect from light.
PRESENTATION
50 mL vials; 50, 100, 150, 200 mL glass or polymer bottles; 100, 125 mL prefilled cartridges
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE NOT A SUBSTITUTE FOR THE ACCOMPANYING
PACKAGE INSERT!
•
VoLumen® is a low density barium sulfate contrast agent especially designed for MDCT (multi-detector row CT) and PET/CT exams to mark the bowel. Volumen is useful for CT studies of the small bowel and mesenteric vessels. Positive oral contrast media may limit the delineation between soft bowel tissues and the lumen and may cause artifacts. Water or methyl-cellulose transits very rapidly and may limit bowel distention and soft tissue differentiation. Volumen, similar to water appears hypodense (low Hounsfield values) on CT scan and can be used in conjunction with IV contrast. VoLumen's low density formulation is well-suited for computed tomography enterography.
Drug Information and Specification
NAME OF COMPOUND
Barium sulfate (BaSO4)
DEVELOPER
INDICATION
Bowel opacification
APPLICATION
Oral, rectal
CONCENTRATION
0.1% w/v, 0.1% w/w barium sulfate suspension
900 mL
PREPARATION
Ready-to-use product
STORAGE
Store at room temperature
PRESENTATION
450 mL bottle
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE NOT A SUBSTITUTE FOR THE ACCOMPANYING
PACKAGE INSERT!
•
Xeromammography or xeroradiography is a breast imaging. Xeroradiography uses photoelectric records of x-ray images on a coated metal plate. Xeromammography as distinct from film-screen mammography uses low-energy photon beams, long exposure times and dry chemical developers. Although xeromammography has sensitivity and specificity comparable with those of a film-screen mammogram, it is not recommended for screening or diagnostic mammography because of maintenance problems and the need for higher breast radiation doses compared with modern low dose mammography equipment. Result Pages : |